Ramon Bertran, Yolanda Becerra, David Carrera, Vincenc Beltran, Marc Gonzalez, Xavier Martorell, Jordi Torres, Eduard Ayguade. UPC-DAC-RR-CAP-2010-18 (Grup de Computació d'Altes Prestacions) Accurate Energy Accounting for Shared Virtualized Environments using PMC-based Power Modeling Techniques . Research Report Departament d'Arquitectura de Computadors (DAC) - UPC, June 2010.

Download

Download paper: Adobe portable document (pdf) PDF

Copyright notice:This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. These works may not be reposted without the explicit permission of the copyright holder.

Abstract

Virtualized infrastructure providers demand new methods to increase the accuracy of the accounting models used to charge their customers. Future data centers will be composed of many-core systems that will host a large number of virtual machines (VMs) each. While resource utilization accounting can be achieved with existing system tools, energy accounting is a complex task when per-VM granularity is the goal. In this paper, we propose a methodology that brings new opportunities to energy accounting by adding an unprecedented degree of accuracy on the per-VM measurements. We present a system –which leverages power models based in performance monitoring counters (PMCs)– to perform energy accounting in virtualized systems. The contribution of this paper is twofold. First, we show that PMC-based power modeling methods are still valid on virtualized environments. And second, we introduce a novel methodology for accounting of energy consumption in virtualized systems. In overall, the results for an Intel R CoreTM 2 Duo show errors in energy estimations below the 5%. Such approach brings flexibility to the chargeback models used by service and infrastructure providers. For instance, we show that VMs executed during the same amount of time, present more than 20% differences in energy consumption

BibTex Reference

@TechReport{bertran-techreport2010-3,
   Author = {Bertran, Ramon and Becerra, Yolanda and Carrera, David and Beltran, Vincenc and Gonzalez, Marc and Martorell, Xavier and Torres, Jordi and Ayguade, Eduard},
   Title = {{UPC-DAC-RR-CAP-2010-18 (Grup de Computació d'Altes Prestacions) Accurate Energy Accounting for Shared Virtualized Environments using PMC-based Power Modeling Techniques }},
   Institution = {Departament d'Arquitectura de Computadors (DAC) - UPC},
   Month = {June},
   Year = {2010}
}

EndNote Reference [help]

Get EndNote Reference (.ref)

Home | Presentation | Teaching | Research | Related Institutions | News Top

Last update: Jan 2, 2015
Copyright © 2000-2015 Departament d'Arquitectura de Computadors
 


It has been automatically generated using the bib2html program.